TRENCH C
Nuclear fuel-shipping cask cleanup debris; tritium and C-14 labeled amino acids and tritium labeled uridine; scrap metal contaminated with DU from burn test; 7.1 Ci tritium pellets; uranyl nitrate; "Dining Car" test hardware; MFP-, DU-, and tritium-contaminated vacuum cleaners; vacuum hose contaminated during cleaning of thorium cloth and thorium cloth debris: concrete crucibles used in reactor safety studies; Kr-85 particle size analyzer: 1,000 lead bricks contaminated with tritium and Na-22; 43 MFP-contaminated lead bricks; 73 each integrated circuits; Ba-133 reactor bolts; flexible glove box dueling; 2 each mechanical vacuum pumps; Sr-90 contaminated carpet; Cs-137 spark gaps; Na-22 cleanup materials, source holders, and shield (1.5 rem/hr on contact); DU-contaminated waste containers; tritium-contaminated vacuum system and power supply; DU billet, hemisphere, and sphere; Pu-238 contaminated hood exhaust hose; Co-60 debris from trailer used to support nuclear fuel-shipping cask; MFP-contaminated hot exhaust system prefilters, HEPA filters, and absolute pressure filters; containerized DU residue, turnings, metal workings, and cuttings; surge voltage arrester; tritium-contaminated pump; irradiated diodes, transistors, capacitors, resistors, circuit boards, voltage regulators, and other miscellaneous electrical components; wooden shipping crates; 13 each Po-210 contaminated static eliminators; one each 62 mCi Se-75 source and one each 1.0 mCi Ta-182 source in sealed A/N can; tritium-contaminated fume hood and exhaust plenum; 2.0 kg deuterium absorbed on vermiculite in sealed A/N can; 12 each 55-gallon drums of MFP-contaminated spent demineralizer resin; DU-contaminated lucite table; 4 each TV cameras; tritium-contaminated ion pump; 1-gallon tritium-contaminated acetone solidified with Safe-T-Set; 24 kg lithium-6 fluoride; 4 each irradiated high-speed cameras, lenses, and one telescope; one each 0.1 mCi Ra-226/Be source encapsulated in concrete-filled A/N can; 2 each DU-contaminated glove boxes; 32.1 Ci tritium; 377 kg DU.Trace Eu-152, Ba-133, 1-129, Na-22, Sr-90, Ni-63, Tc-99, Gd-153, Ag-IIOm, Pm-147, Sr-85, Sb-125, Ta-182, Ge-68, Mn-54, and Fe-55.1,159 cu ft of TA-5 routine operational and miscellaneous decontamination waste